Voltas AC Error Code List 2025 [E1,E2,E3,F1] NEW

As you know Indian summer became a pressure cooker because in India nowadays heat increases day by day in summer. Hence, every person in India wants AC or air conditioner for their home, so there are a lot of AC companies which give hug discount. Hence, people start buying AC even middle class of also want to buy AC as you know every electronic items diagnose with problem so in AC there are a lot of problem occurs while using AC in summer, the case of AC it shows some error code different AC company have different error code in this article I am going to give you a list of Voltas AC error code. So be with this blog and read carefully because this error code is updated from time to time, because every year the AC company launches its new variant.

What Are Voltas AC Error Codes?

AC error code means when your AC go through some trouble or problem, then it shows some error code just like E1, E2 and etc. If you already know about the error code then it is easy for you to know what actually happening with your AC and along with this if you contact your customer care to complain for AC day should also ask what’s error code it’s showing so you have to know Voltas AC error code list. There are some common reasons when these error code appears just like if your AC running out of CFC gas or having a problem in the compressor or even having electricity short circuit in its PVC plate, then these code appears in the display area of your AC.

Voltas AC Error Code List 2025

Voltas AC comes in four types and each types of Voltas AC have a different error code so in below paragraph and chart I am going to share respected Voltas AC error code list of 2025

Split AC Error Codes (Voltas)

Error CodeMeaning / FaultPossible Solution / Action
E1Indoor ↔ Outdoor communication errorCheck communication wiring (connectors, continuity). Reset unit.
E2Indoor coil sensor faultTest or replace indoor coil temperature sensor.
E3Compressor overload or overcurrentCheck compressor, wiring, possible blockage or overcharge.
E4Indoor room sensor faultInspect room (ambient) sensor, wiring.
E5Outdoor coil sensor faultCheck outdoor sensor and its connection.
E6Outdoor unit malfunction / faultInspect outdoor PCB, fan, wiring.
F1Low refrigerant / Gas leakCheck refrigerant level, detect & repair leaks.
F2High / Low pressure protectionInspect piping, pressure sensors.
F3 / F4 / F5 etc.Other protection or sensor faults (varies)Diagnose specific sensor or protection circuit.

Window AC Error Codes (Voltas)

Error CodeMeaning / FaultPossible Solution / Action
E1Indoor / outdoor communication issueCheck wiring and communication cables.
E2Room sensor errorTest or swap out the room / ambient sensor.
E4Indoor PCB / control errorInspect PCB for damage, loose connections.
F1Refrigerant low / gas leakageRecharge refrigerant, fix leaks.
F2Pressure protection triggeredInspect piping, clean filters, check blockages.
(Other codes)Varies by modelConsult user manual or service center

Inverter AC Error Codes (Voltas)

Error CodeMeaning / FaultPossible Solution / Action
E1Communication error (indoor-outdoor)Check communication lines, connectors, polarity.
P0Inverter module (IPM) faultInspect / replace the inverter / IPM module.
P4IPM overload errorCheck compressor wiring, motor, and overload protection.
P1Voltage high / lowEnsure stable voltage supply; use stabilizer.
L3 / “33” blinkDrive phase current overloadDiagnose three-phase motor or circuit overload.

Cassette & Tower AC Error Codes (Voltas)

Error CodeMeaning / FaultPossible Solution / Action
E1Indoor / outdoor communication errorCheck the interconnecting cable and connectors.
E2Indoor sensor / coil sensor problemInspect or replace sensor.
E6Outdoor unit faultCheck fan, motor, wiring, PCB.
F1Low refrigerant / leakRecharge refrigerant, repair leaks.
P0 / P4Inverter / IPM module errorInspect or replace inverter circuitry.
Voltas AC Error Code List

Detailed Explanation of Common Error Codes

Some common Voltas AC error code is like when it shows E1 then it’s means indoor and outdoor communication error and when it shows E2 then it’s means indoor coil sensor problem just like this there are many other Voltas AC error code some examples I have given below.

Example

Error E1 – Indoor / Outdoor Communication

Error E2 – Indoor Coil Sensor

Error E6 – Outdoor Unit Malfunction

Error E7 – Fan Motor Fault

Error F1 – Low Refrigerant Level P0/P1/P4 – Inverter Module Errors

How to Reset Voltas AC After Error Code

If you want to reset your Voltas AC after solving error code problem than you have to click reset button on your Voltas AC remote button and then turn off your AC from main source and after sometime restart it and you saw your Voltas AC working properly.

There some conditions When resetting works and when it doesn’t , if there is hardware problem inside your Voltas AC it might be in Indoor part orthe outdoor part then reset not work in this case you have to call your AC service care customer and then they will send a technician and that technician solve your issue.

DIY Troubleshooting Tips

I want to give you some advice if you have AC specific Voltas AC then you have to clean it frequently there is two type of cleaning first one is Deep cleaning and second one is soft cleaning soft cleaning can we done by you if you are willing to do it, for cleaning your voltas AC you have to genetically remove the front session of your from where cool air comes.

You have to remove air filter from your Voltas AC and then you have to clean it and after cleaning you have to dry it and re put it at the place from where you have remove this Voltas AC air filter.

  • Check power supply & wiring
  • Clean air filters regularly
  • Ensure outdoor unit has ventilation
  • Reset remote settings

When to Call Customer Support

If you want to connect with customer support of Voltas AC then in this paragraph I have given below some contact number and mail ID of Voltas AC from where you can take the help.

  • Issues that need professional help.
  • Voltas AC customer care number & service center details.

Preventive Maintenance to Avoid Errors

If you want to avoid error in your voltage AC then you have to regular servicing check refrigerant level proper installation seasonal maintenance before uses and a good stabilizer.

  • Regular servicing
  • Checking refrigerant levels
  • Proper installation tips
  • Seasonal maintenance before summer

FAQs on Voltas AC Error Codes 2025

What does E1 error mean in Voltas AC?

If you see E1 error in your Voltas AC, your indoor and outdoor unit have some connection problem.

How do I fix E2 error?

This error appears when indoor coil sensor have some problem.

Can I run AC if error code is showing?

No if your AC shows some error than responsive to your AC technician or you can visit our website for checking which error code have which meaning.

Are error codes same for all Voltas models?

Almost all Voltas AC have same error code but some are difference in inverter AC, inverter AC, and window AC

Conclusion

If you want to run your Voltas AC for a long time, then you have to know and understand each and every error code of Voltas AC this will help you to maintain the lifetime of your AC.

I hope you love my article on Voltas AC error code if you want to ask something related to it then please comment below in the comment section I will try to reply you as soon as possible.

Keywords:- Voltas AC error code list, Voltas AC troubleshooting guide, Voltas AC error codes E1 E4 E3, Voltas split AC error codes, Voltas inverter AC error codes and solutions, Common Voltas AC error codes list

Leave a Comment